来宝网Logo

热门词:生物显微镜 水质分析仪 微波消解 荧光定量PCR 电化学工作站 生物安全柜

AED
现在位置首页>实验室原料试剂耗材>生化试剂>ELISA试剂盒>大鼠胰岛素样生长因子1(IGF1) ELISA Kit DL-IGF1-Ra
大鼠胰岛素样生长因子1(IGF1) ELISA Kit DL-IGF1-Ra
大鼠胰岛素样生长因子1(IGF1) ELISA Kit DL-IGF1-Ra
  • 大鼠胰岛素样生长因子1(IGF1) ELISA Kit DL-IGF1-Ra

大鼠胰岛素样生长因子1(IGF1) ELISA Kit DL-IGF1-Ra

产品报价:2070元

更新时间:2018/4/11 9:25:23

地:江苏

牌:dldevelop

号:DL-IGF1-Ra

厂商性质: 生产型,贸易型,

公司名称: 无锡市东林科技发展有限责任公司

产品关键词: IGF1   dldevelop   大鼠胰岛素样生长因子   大鼠elisa试剂盒  

383
访问人数
0
累计评论


郭蓓蓓 : (17809162583) (021-61431509)

(联系我时,请说明是在来宝网上看到的,谢谢!)


大鼠胰岛素样生长因子1(IGF1) ELISA Kit DL-IGF1-Ra

The kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of IGF1 in rat serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids.

Reagents

Quantity

Reagents

Quantity

Pre-coated, ready to use 96-well strip plate

1

Plate sealer for 96 wells

2

Standard

2

Standard Diluent

1×20mL

Detection Reagent A

1×120μL

Assay Diluent A

1×12mL

Detection Reagent B

1×120μL

Assay Diluent B

1×12mL

TMB Substrate

1×9mL

Stop Solution

1×6mL

Wash Buffer (30 × concentrate)

1×20mL

Instruction manual

1

 SENSITIVITY

The minimum detectable dose of IGF1 is typically less than 30pg/mL.

The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined by adding two standard deviations to the mean optical density value of twenty zero standard replicates and calculating the corresponding concentration.

 

大鼠胰岛素样生长因子1(IGF1) ELISA Kit DL-IGF1-Ra

 SPECIFICITY

This assay has high sensitivity and excellent specificity for detection of IGF1.

No significant cross-reactivity or interference between IGF1 and analogues was observed.

Note:

Limited by current skills and knowledge, it is impossible to perform all possible cross-reactivity detection tests between IGF1 and all analogues, therefore, cross reactivity may still exist.

 

大鼠胰岛素样生长因子1(IGF1) ELISA Kit DL-IGF1-Ra

 PRECISION

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level IGF1 were tested 20 times on one plate, respectively.

Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level IGF1 were tested on 3 different plates, 8 replicates in each plate.

CV(%) = SD/meanX100

Intra-Assay: CV<10%

Inter-Assay: CV<12%

 

 STABILITY

The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions.

Note:

To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity, and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.