For use with most hand tools, power tools or rotational measurement applications. The common "brush bounce" that plagues the accuracy testing of pulse tools is cured when using a brushless rotary transducer. Connects between the power tool and the joint. Monitors actual torque being applied from the driver to the fastener. Features an instant auto-recognition system of the BLRTSX connected to the PTT.  Features

Accuracy +/-.25% of full scale Use with most hand tools, power tools or rotational measurement applications The common "brush bounce" that plagues the accuracy testing of pulse tools is cured when using a brushless rotary transducer Connects between the power tool and the joint. Monitors actual torque being applied from the driver to the fastener Bi-directional
 Torque Ranges

| Model | Range | Input Drive | Output Drive | | BLRTSX28z-H | 10 - 28 Oz-in | 1/4" M/Hex | 1/4" F/Hex | | BLRTSX70z-H | 10 -70 Oz-in | 1/4" M/Hex | 1/4" F/Hex | | BLRTSX140z-H | 25 - 140 Oz-in | 1/4" M/Hex | 1/4" F/Hex | | BLRTSX18i-H | 2 - 18 Lb-in | 1/4" M/Hex | 1/4" F/Hex | | BLRTSX50i-H | 5 - 50 Lb-in | 1/4" M/Hex | 1/4" F/Hex | | BLRTSX50i | 5 - 50 Lb-in | 1/4" F/Sq | 1/4" M/Sq | | BLRTSX100i-H | 10 - 100 Lb-in | 1/4" M/Hex | 1/4" F/Hex | | BLRTSX100i | 10 - 100 Lb-in | 1/4" F/Sq | 1/4" M/Sq | | BLRTSX160i-H | 16 - 160 Lb-in | 1/4" M/Hex | 1/4" F/Hex | | BLRTSX160i | 16 - 160 Lb-in | 1/4" F/Sq | 1/4" M/Sq | | BLRTSX18F | 2 - 18 Lb-ft | 3/8" F/Sq | 3/8" M/Sq | | BLRTSX36F | 4 - 36 Lb-ft | 3/8" F/Sq | 3/8" M/Sq | | BLRTSX73F | 8 - 73 Lb-ft | 1/2"? F/Sq | 1/2"? M/Sq | | BLRTSX118F | 12 - 118 Lb-ft | 1/2"? F/Sq | 1/2"? M/Sq | | BLRTSX184F | 19 - 184 Lb-ft | 3/4"? F/Sq | 3/4"? M/Sq | | BLRTSX368F | 37 - 368 Lb-ft | 3/4"? F/Sq | 3/4"? M/Sq | | BLRTSX738F | 74 - 738 Lb-ft | 1"? F/Sq | 1"? M/Sq |
The available engineering units of measurement on the BLRTSX Rotary Torque Transducers are oz-in, lb-in, lb-ft, cN-m and N-m.  Specifications

| Output at Rated Capacity | > 6 Nm [53 lbf.in] rated torque 2 mV/V | | Interchanegeability | Matched for mv/v and shunt calibration +0.3% FS | | Nonlinearity | +0.2% FS | | Excitation Recommended | 10V DC or AC RMS | | Bridge Resistance | 350 ohms | | Usable Temperature Range | 41-122 degrees F | | Safe Overload | 125% of rated output |
 Related Products

PTT Torque Analyzer
|  |

LTT Torque and Angle Analyzer
|  |
|