来宝网Logo

热门词:生物显微镜 水质分析仪 微波消解 荧光定量PCR 电化学工作站 生物安全柜

AED
现在位置首页>医疗器械>体外诊断试剂>分子诊断试剂>A-172, A-172 Humane Glioblastom Zell-Linie 300108(330108)
A-172, A-172    Humane Glioblastom Zell-Linie    300108(330108)
A-172, A-172    Humane Glioblastom Zell-Linie    300108(330108)
  • A-172, A-172    Humane Glioblastom Zell-Linie    300108(330108)

A-172, A-172 Humane Glioblastom Zell-Linie 300108(330108)

产品报价:询价

更新时间:2014/8/22 15:24:42

地:美国

牌:cell-lines-service

号:A-172

厂商性质: 生产型,贸易型,服务型,

公司名称: 北京百杰生物科技有限公司

产品关键词:

153
访问人数
0
累计评论


李胜亮 : (13466675923) (13466675923)

(联系我时,请说明是在来宝网上看到的,谢谢!)


Designation:A-172
Depositor:Giard
Organism:Homo sapiens (human)
Age/Stage:53 years
Gender:male
Tissue:brain
Celltype:glioblastoma
Growth Properties:monolayer
Description:The A-172 cell line was established by D.J. Giard in 1973.
Culture Medium:DMEM : Ham’s F12 medium (1:1 mixture) supplemented with L-glutamine and 5% FBS (MG-40, CLS order number 820400).
Subculturing:Remove medium and rinse the adherent cells using PBS without calcium and magnesium (3-5 ml PBS for T25, 5-10ml for T75 cell culture flasks). Add Accutase (1-2ml per T25, 2.5ml per T75 cell culture flask), the cell sheet must be covered completely. Incubate at 37°C for 10 minutes. Carefully resuspend the cells, the addition of medium is optional but not necessary, and dispense into new flasks which contain fresh medium.
Split Ratio:A ratio of 1:3 to 1:8 is recommended
Fluid Renewal:every 2 to 3 days
Freeze Medium:CM-1 (CLS order number 800125 or 800150)
Sterility:Tests for mycoplasma, bacteria and fungi were negative
Biosafety Level:1
Tumorigenic:no
DNA Profile (STR):Amelogenin: X,Y
CSF1PO: 9,12
D13S317: 11
D16S539: 12
D5S818: 11,12
D7S820: 11
THO1: 6,9.3
TPOX: 8,11
vWA: 20
D3S1358: 14,18
D21S11: 28,32.2
D18S51: 12,13
Penta E: 5,10
Penta D: 9,13
D8S1179: 13,14
FGA: 20,22
CLS ? Cell Lines Service, 2010.


References:

Giard DJ et al. In vitro cultivation of human tumors: establishment of cell lines derived from a series of solid tumors. J Natl Cancer Inst 51: 1417-23, 1973.
Pinkerton H and Rana MW. Cytotoxic effects of 1,3-bis(2 chloroethyl)-1-nitrosourea (BCNU) on cultured human glioblastomas. Proc Soc Exp Biol Med 151:532-4, 1976.
Olopade OI et al. Molecular analysis of deletions of the short arm of chromosome 9 in human gliomas. Cancer Res 52: 2523-9, 1992.
Debinski W et al. Receptor for interleukin (IL) 13 does not interact with IL4 but receptor for IL4 interacts with IL13 on human glioma cells. J Biol Chem 271: 22428-33, 1996.
Cordes N et al. beta1-integrin-mediated signaling essentially contributes to cell survival after radiation-induced genotoxic injury. Oncogene 25: 1378-90, 2006.
Ohnishi K et al. Induction of radiation resistance by a heat shock protein inhibitor, KNK437, in human glioblastoma cells. Int J Radiat Biol 82: 569-75, 2006.
Shirato K et al. Phenoxazine derivatives induce caspase-independent cell death in human glioblastoma cell lines, A-172 and U-251 MG. Oncol Rep 17: 201-8, 2007.