来宝网Logo

热门词:生物显微镜 水质分析仪 微波消解 荧光定量PCR 电化学工作站 生物安全柜

AED
现在位置首页>医疗器械>体外诊断试剂>分子诊断试剂>MEWO, MEWO Humane Haut Melanom Zell-Linie 300285 (330285)
MEWO, MEWO     Humane Haut Melanom Zell-Linie    300285  (330285)
MEWO, MEWO     Humane Haut Melanom Zell-Linie    300285  (330285)
  • MEWO, MEWO     Humane Haut Melanom Zell-Linie    300285  (330285)

MEWO, MEWO Humane Haut Melanom Zell-Linie 300285 (330285)

产品报价:询价

更新时间:2014/8/22 14:33:03

地:美国

牌:cell-lines-service

号:MEWO

厂商性质: 生产型,贸易型,服务型,

公司名称: 北京百杰生物科技有限公司

产品关键词:

160
访问人数
0
累计评论


李胜亮 : (13466675923) (13466675923)

(联系我时,请说明是在来宝网上看到的,谢谢!)


Designation:MEWO
Depositor:CLS
Organism:Homo sapiens (human)
Ethnicity:Caucasian
Tissue:melanoma, malignant; skin
Morphology:stellate
Growth Properties:adherent
Description:Product melanin, derived from a human melanoma by Prof.C.Grose (1978). The cells support growth of varicella-zoster virus (VZV) isolates at 36°C although growth is optimal at 32°C.
Culture Medium:Minimum essential medium (Eagle) in Earle's BSS supplemented with 2 mM L-glutamine, 1% non-essential amino acids,  1 mM sodium pyruvate and 10% fetal bovine serum (MG-10, CLS order number 820100).
Subculturing:Remove medium and rinse the adherent cells using PBS without calcium and magnesium (3-5 ml PBS for T25, 5-10ml for T75 cell culture flasks). Add Accutase (1-2ml per T25, 2.5ml per T75 cell culture flask), the cell sheet must be covered completely. Incubate at 37°C for 10 minutes. Carefully resuspend the cells, the addition of medium is optional but not necessary, and dispense into new flasks which contain fresh medium.
Split Ratio:A ratio of 1:3 to 1:6 is recommended
Fluid Renewal:2 to 3 times per week
Freeze Medium:CM-1 (CLS order number: 800125, 25ml, 800150, 50ml)
Sterility:Tests for mycoplasma, bacteria and fungi were negative
Biosafety Level:1
Tumorigenic:yes, in nude mice; forms malignant melanoma
DNA Profile (STR):Amelogenin: X / Y
CSF1PO: 12/12
D13S317: 8/9
D16S539: 10/12
D5S818: 12/13
D7S820: 10/12
THO1: 7/9
TPOX: 8/10
vWA: 15/15
D3S1358: 17/17
D21S11: 30/32.2
D18S51: 14/17
Penta E: 5/5
Penta D: 10/10
D8S1179: 13/15
FGA: 22/22
CLS ? Cell Lines Service, 2009.
Viruses:SMRV negative, as confirmed by Real-Time PCR
Applications:Virus studies


References:

Puche JG et al. Complement-dependent serum cytotoxicity of cancer patients studied by 51Cr release assay on human cancer lines. Tumori 63: 97-108, 1977.
Kadish AS et al. Interfreon as a mediator of human lymphocyte supression. J Exp Med 151: 637-50, 1980.
Denkert C et al. Expression of cyclooxygenase 2 in human malignant melanoma. Cancer Res 61: 303-8, 2001.
Christmann M et al. Acquired resistance of melanoma cells to the anti-neoplastic agent fotemustine is caused by reactivation of the DNA repair gene MGMT. Int J Cancer 92:123-9, 2001.
Schirrmacher V et al. Antitumor effects of Newcastle Disease Virus in vivo: local versus systemic effects. Int J Oncol 18: 945-52, 2001.
Chen H et al. The role of phosphoinositide-3-kinase in the soring and transport of newly synthesized tyrosinase-related protein-1 (TRP-1). J Investig Dermatol Symp Proc 6: 105-14, 2001.
De Nardo C et al. Recombinant transmembrane CD59 (CD59-TM) confers complement resistance to GPI-anchored protein defective melanoma cells. J Cell Physiol 190: 200-6, 2002.
Shannan B et al. Clusterin /CLU) and melanoma growth: CLU is expressed in malignant melanoma and 1,25-dihydroxyvitamin D3 modulates expression of CLU in melanoma cell lines in vitro. Anticancer Res 26: 2707-16, 2006.
Munshi A et al. Vorinostat, a histone deacetylase inhibitor, enhances the response of human tumor cells to ionizing radiation through prolongation of gamma-H2AX foci. Mol Cancer Ther 5: 1967-74, 2006.