现在位置首页>行业专用>石油行业专用仪器>闪点仪/燃点仪>SYD-0633液体石油沥青闪点试验器
SYD-0633液体石油沥青闪点试验器
SYD-0633液体石油沥青闪点试验器
  • SYD-0633液体石油沥青闪点试验器

SYD-0633液体石油沥青闪点试验器

产品报价:询价

更新时间:2017/6/19 16:54:14

地:湖北

牌:

号:SYD-0633

厂商性质: 生产型,

公司名称: 武汉格莱莫检测设备有限公司

产品关键词:

346
访问人数
0
累计评论


薛晴 : (13545068882) (027-86619996)

(联系我时,请说明是在来宝网上看到的,谢谢!)


 

武汉格莱莫检测设备有限公司 电话:13545068882 027-86619889

传真:027-86619889   网址:www.glmgs.com

一、产品简介
One, product introduction
SYD-0633液体石油沥青闪点试验器(泰格开口杯法) 是按照国家行业标准JTJ052《公路工程沥青及沥青混合料试验规程》中的T0633《液体石油闪点试验(泰格开口杯)》规定的要求设计制造的,适用于测定闪点低于93℃的液体石油沥青材料的闪点。
SYD-0633 liquid petroleum pitch tester ( tiger cup method ) is in accordance with the national industry standard JTJ052" highway engineering asphalt and asphalt mixture test procedures in the" T0633" liquid oil flash point test ( tag )" in accordance with the requirements of design and manufacturing, was applied to the determination of flash point below 93 DEG liquid petroleum asphalt material for flash.
二、技术指标
Two, technical indicators
★工作电源:AC 220V±10%,50Hz。
Of working power: AC 220V + 10%, 50Hz.
★试样杯:金属坩埚(代替玻璃制泰格开口杯),深47mm,上口直径Ф64mm,下口直径Ф38mm,距上口边缘3.2mm内壁还有一道刻线。
In the sample cup: metal crucible ( instead of glass tag ), deep 47mm, opening diameter with 64mm, mouth diameter with 38mm, from the upper edge of the inner wall and a 3.2mm.
★点火器:由进气管、气流调节阀和火焰比较球组成,喷口直径Ф0.7mm~0.8mm,按照试验方法规定,可把火焰调节成直径4mm球形火焰。
Of ignition: consists of inlet pipe, air flow regulating valve and the flame ball, nozzle diameter with 0.7mm ~ 0.8mm, in accordance with the provisions of the flame test methods, can be adjusted to 4mm Diameter spherical flame.
★电炉:由电热丝和电炉盘组成,并可根据使用要求通过加热调节器控制升温速度。
In: by the electric heating wire and electric furnace disk, and according to the use requirements through the heating control temperature rising speed.
★温度计:0℃~+100℃,最小分度值1℃,符合T0633标准的规定。
In 0 DEG C thermometer: 100, indexing angle 1 degrees, in line with the T0633 standards.
★控制装置:分别由电子调压线路和半自动点火装置组成。
In the control device: respectively by the electronic voltage line and semi automatic ignition device.
★量规:厚度3.2mm,下面各有2个3.2±0.25mm的突起,距底部3.2mm处有直径各为Ф4.0mm及Ф0.8的孔。
Of gauge: thickness 3.2mm, each of the following 2 3.2 + 0.25mm protrusions from the bottom, 3.2mm has diameter each with 4.0mm and with 0.8 holes.
★环境温度:≤35℃。
Ambient temperature below 35 DEG C:.
★相对湿度:≤85%
Relative humidity: less than or equal to 85%.
三、基本配置
Three, the basic configuration
★SYD-0633型液体石油沥青闪点试验器
SYD-0633 type liquid asphalt oil flash point tester
★试样杯
Of the test cup
★点火器
Of ignition
★温度计(0~100℃,最小分度1℃)
Of the thermometer ( 0 to 100 DEG C, the smallest division 1 DEG C )
★温度计架
Thermometer holder.
★电热丝
Of electric wire
★量规
Of gauge
★硅胶管(6×9)
Of silicone tube ( 6 x 9 )