PFA-PRA Filters for Blind well and Boyden chambers
PFA-PRA Filters for Blind well and Boyden chambers
  • PFA-PRA Filters for Blind well and Boyden chambers

PFA-PRA Filters for Blind well and Boyden chambers

产品报价:询价

更新时间:2019/1/22 13:46:26

地:美国

牌:neuroprobe

号:PFA-PRA

厂商性质: 生产型,贸易型,服务型,

公司名称: 世联博研(北京)科技有限公司

产品关键词: PFA-PRA   Filters for Blind well and Boy   聚碳酸酯轨道蚀刻膜  

450
访问人数
0
累计评论


程园 : (18611717737) (010-57129142)

(联系我时,请说明是在来宝网上看到的,谢谢!)


Blind well和Boyden室的过滤器

盲孔和Boyden的单井室使用直径为13mm的过滤器。售出100多个。

毛孔大小为2μm3μm的为5μm为8μm为10μm12μm的
标准PCTEPFA2PFA3PFA5PFA8PFA10PFA12
PCTE w / PVP-PRA3PRA5PRA8-

有关其他孔径的价格和可用性,请联系我们

聚碳酸酯轨道蚀刻(PCTE)膜是我们的腔室和仪器系统中使用的主要类型的过滤器。这是一种非常薄的膜,标称厚度在6-10μm之间。这种膜类型具有优异的孔径和密度均匀性,以及其他优点,如低可萃取性,低蛋白质结合和可忽略的吸收。这些特性使其非常适用于趋化性测定以及其他高纯度筛选测定。

PVP处理 - PCTE膜可用润湿剂聚乙烯吡咯烷酮(PVP)预处理,使表面具有亲水性。当介质溶液不能自身润湿膜时,使用PVP处理的膜。这主要发生在使用非常小的孔径或高粘度介质溶液时。某些细胞类型如嗜中性粒细胞不能很好地粘附于PVP处理的膜上,并且在迁移后趋于脱落。虽然在量化过滤器上的细胞时这是有问题的,但是一些使用ChemoTx?系统或MB系列96孔腔室并在板中量化的研究人员发现这是一个优势。细胞外基质蛋白质也不能很好地粘附于PVP处理的膜上。如果您的分析需要这样的涂层,我们建议使用不含PVP的膜。

聚碳酸酯膜有以下孔径和相应的孔密度:

孔径(+ 0 / -20%)为2μm3μm的为5μm为8μm10或12μm
密度(毛孔/ cm 2
(公差+/- 15%)
2 x 10 62 x 10 64 x 10 51 x 10 51 x 10 5

 

细胞类型以外的许多因素进入孔径选择过程。

Filters for Blind well and Boyden chambers

Single-well chambers, both blind well and Boyden, use 13mm diameter filters. Sold in lots of 100.

Pore Size2μm3μm5μm8μm10μm12μm
Standard PCTEPFA2PFA3PFA5PFA8PFA10PFA12
PCTE w/PVPPRA3PRA5PRA8

Please contact us for pricing and availability on other pore sizes

Polycarbonate track-etch (PCTE) membranes are the primary type of filters used in our chambers and instrument systems. This is a very thin membrane ranging between 6-10μm in nominal thickness. This membrane type offers、 excellent uniformity in pore size and density, as well as other benefits such as low extractables, low protein binding, and negligible absorption. These characteristics make it ideally suited for use in chemotaxis assays as well as other high purity screening assays.

PVP Treatment –PCTE membranes are available pre-treated with the wetting agent polyvinylpyrrolidone (PVP) which makes the surface hydrophilic. PVP-treated membranes are used when the media solutions cannot wet out the membrane by themselves. This occurs primarily when working with very small pore sizes or high viscosity media solutions. Certain cell types such as neutrophils、 do not adhere well to PVP treated membranes and tend to drop off after migrating. While this is problematic when quantifying cells on the filter, some researchers using the ChemoTx? sytem or the MB-series 96-well chambers and quantifying in the plate find this to be an advantage. Extra-cellular matrix proteins do not adhere well to PVP treated membranes either. If your assay requires such coating, we recommend using PVP-free membranes.

Polycarbonate membranes are available in the following pore sizes and corresponding pore densities:

Pore size (+0/-20%)2μm3μm5μm8μm10 or 12μm
Density (pores/cm2)
(tolerance +/- 15%)
2 x 1062 x 1064 x 1051 x 1051 x 105

 

Many factors other than cell type enter into the pore size selection process.