空气采样器系统包括探测器和采样网管。探测器由吸气泵、过滤器、激光探测腔、控制电路、显示电路等组成。吸气泵通过PVC管或钢管所组成的采样管网,从被保护区内连续采集空气样品放入探测器。空气样品经过过滤器组件滤去灰尘颗粒后进入探测腔,探测腔有一个稳定的激光光源。烟雾粒子使激光发生散射,散射光使高灵敏的光接收器产生信号。经过系统分析,完成光电转换。烟雾浓度值及其报警等级由显示器显示出来。主机通过继电器或通讯接口将电信号传送给火灾报警控制中心和集中显示装置。
空气采样器探测系统的探测原理是靠主机内部的抽气泵,透过延伸至探测区域的空气采样管路将空气样品抽回侦测室进行检测,当空气样品中检测物质的浓度达到一定程度时,系统即发出警报。
SKC采样器225-1主图:
SKC采样器配件225-13-3:
SKC采样器配件225-13-5A:
SKC BioSampler是一个具有专利(Patented 5,902,385)的高效率玻璃冲击瓶捕集装置的特殊设计,它需要一台高流量音速的空气采样泵,225-1采样器配件 用来捕集空气中微生物(如细菌、真菌、花粉、病毒)与其副产物如内毒素、霉菌毒素及其它碎片,以供进一步分析。BioSampler有三个切线式弯度的喷嘴头,具决定性的或音速(sonic flow)的小孔,每孔允许4.2公升/分钟的空气通过共同组成的流量,达到约12.5公升/分钟的流速。容许有效捕集总生物气胶或活生物气胶有效时间达8小时以上
224-PCXR8产品简介:
224-PCXR8是一个恒定的流量空气采样泵,应用广泛
可在计算机上适用,操作容易,并允许无人采样期间7天
具有高背压补偿
可以安静运行
具有宽的流量范围
质量可靠,质保一年
224-PCXR8其采用国家的最先进的气动系统提供恒定的流量
使用户可以得到准确的空气量,无需频繁调整采样
所有SKC XR系列通用空气采样泵都配备了不锈钢皮带扣
具有多管采样能力
具有可编程定时系统
具有间歇采样能力
225-1采样器配件应用范围:
SKC采样器225-1室内空气质量调查
一般医院与兽医院内的疾病感染控制
SKC采样器配件225-1农业粉尘中微生物之定量化
SKC采样器225-1生物及微生物研究
公共建筑物内疾病感染之调查
食品处理与加工制造厂卫生安全之管制
造纸厂或废水处理工作场所之生物污染暴露
225-1采样器配件BioSampler225-9595的优点:
具专利的旋转液体方法,可减低粒状物胶合,并降低再气胶化
采用非蒸发性液体做为捕集液,例如矿物油(ViaTrap),黏度较水溶液高,可提供最佳的捕集效能
捕集时程可超过8小时,且捕集效率可维持恒常稳定
可保存微生物之完整及可活度
全玻璃设计,易清洗、杀菌、高压灭菌与重复使用
(Patented 5,904,752)。 Assessments of microbiological air quality are useful for studies of the airborne transmission of pathogens and of other biological particles in the air that may cause noninfectious diseases (such as allergy to pollen). The two principle methods of assessing microbiological air quality are passive monitoring and active sampling. Both methods were designed for studies of airborne bacteria or fungi. Passive monitoring is typically performed using settle plates, which are opened and exposed to the air for a given time, then incubated and resulting bacterial and fungal colonies are analyzed. Active sampling is performed with a microbiological air sampler that mechanically draws a known volume of air over, or through, a particle collection device. The particles are subsequently removed from the collection medium and analyzed. Air samplers are also used to collect airborne viruses, but it is difficult to do so primarily due to their small size and relatively low concentration in ambient air. Also, most of the available bioaerosol samplers are not suitable for the collection of viruses for reasons that include (a) they typically run for short periods of time (min), making it difficult to capture large volumes, (b) most do not separate particles by size, and (c), they are inefficient at collecting submicron particles
更多采样器相关资料:
Aircheck2000美国SKC空气采样器http://www.afzhan.com/st52391/product_1388599.html