LVCN210-G-B_LVCN210-G超声波液位变送器OMEGA
范先生 : (15221105376) (15221105376)
(联系我时,请说明是在来宝网上看到的,谢谢!)范先生 : (15221105376) (15221105376)
(联系我时,请说明是在来宝网上看到的,谢谢!)LVCN210-G-B_LVCN210-G超声波液位变送器OMEGA
LVCN210-G-B_LVCN210-G超声波液位变送器OMEGA
液位检测、开关和控制功能高达3米(9.8英尺)
通过免费软件下载和USB适配器快速轻松配置
窄5.08厘米(2“)光束宽度和短10厘米(4”)死区
四个可编程继电器
PVDF传感器和6P聚碳酸酯外壳
Memory: Non-volatile
Supply Voltage: 24 Vdc (loop)
Consumption: 0.5 W
Loop Resistance: 400Ω max
Signal Output: 4 to 20 mA, two-wire
Signal Invert: 4 to 20 mA or 20 to 4 mA
Signal Fail-Safe: 4 mA, 20 mA, 21 mA, 22 mA or hold last
Contact Type: (4) SPST relays
Contact Rating: 60 VA, 1A max
Contact Fail-Safe: Power loss; Hold last
Echo Loss: Open, close or hold last
Hysteresis: Selectable
Process Temp: -7 to 60°C (20 to 140°F)
Temp Comp: Automatic
Ambient Temp: -35 to 60°C (-31 to 140°F)
Pressure: Maximum Working Pressure = 2 bar (30 psi)
Enclosure Rating: Type 6P, encapsulated, corrosion resistant and submersible
Enclosure Material: Polycarbonate
Trans. Material: PVDF
Cable Jacket Mat: Polyurethane
Cable Type: 9-conductor, shielded
Cable Length: 1.2 m (48")
Process Mount: 1 NPT (1" G optional)
Mount Gasket: FKM
Classification: General purpose
Compliance: CE, RoHS
精确测量的自动温度补偿
欧米茄的LVCN210系列超声波液位变送器和控制器提供高达3米(9.8’)的连续液位测量和4至20毫安的信号输出,并通过我们的免费软件下载进行配置。液位传感器有4个可编程继电器,具有可选滞后和故障安全逻辑。嵌入式控制器可以通过更换外部控制硬件来降低成本。这种非接触式液位传感器非常适合腐蚀性、粘性或脏液体,广泛用于日用罐、撬块、中型散货箱、集水坑和工艺罐的液位应用。