来宝网Logo

热门词:生物显微镜 水质分析仪 微波消解 荧光定量PCR 电化学工作站 生物安全柜

山东博科
现在位置首页>自动化仪器仪表>流量仪表>质量式流量计>FMC-5505GA_FMC-5506GA_FMC-5507GA质量流量计OMEGA欧米茄
FMC-5505GA_FMC-5506GA_FMC-5507GA质量流量计OMEGA欧米茄
FMC-5505GA_FMC-5506GA_FMC-5507GA质量流量计OMEGA欧米茄
  • FMC-5505GA_FMC-5506GA_FMC-5507GA质量流量计OMEGA欧米茄

FMC-5505GA_FMC-5506GA_FMC-5507GA质量流量计OMEGA欧米茄

产品报价:询价

更新时间:2019/7/16 22:54:19

地:美国

牌:欧米茄

号: FMC-5505GA

厂商性质: 贸易型,

公司名称: 上海茂培电子科技有限公司

产品关键词: FMC-5507GA   FMC-5506GA   FMC-5505GA   欧米茄   omega  

16
访问人数
0
累计评论


范先生 : (15221105376) (15221105376)

(联系我时,请说明是在来宝网上看到的,谢谢!)


FMC-5505GA_FMC-5506GA_FMC-5507GA质量流量计OMEGA欧米茄

流量范围:见下表


连接:ANSI、DIN、JIS或卫生型三夹法兰


最大压力:16巴(230磅/平方英寸),[可选:25巴(360磅/平方英寸),40巴(580磅/平方英寸)和63巴(913.7磅/平方英寸)]


本体材质:304不锈钢


测量管材质:316 L SS


工艺温度范围:


集成型:-50至125°C(-58至257°F)


远程型(-R):-50至200°C(-58至392°F)


环境温度:-40至55°C(-40至131°F)


工作湿度:25°C(77°F)时,相对湿度为(5至95%)。


流量精度/重复性:


FMC-5100:0.1/0.05%(仅液体)


FMC-5200:0.2/0.1%(仅液体)


FMC-5500:0.5/0.25%


密度测量:


范围:0.2至3.0 g/cm3


误差:±0.002 g/cm3


重复性:0.001 g/cm3


温度精度:±1.0°C


保护:NEMA 4X(IP65)


批准:CE、RoHS


通信:RS485(RTU Modbus?)、HART?(HART选项)


脉冲输出:0至10 kHz,±0.075%满刻度


电流输出:4至20 mA,满量程0.005%


电源:18至36 Vdc,85至265 Vac(-AC选项),15 W

FMC-5505GA_FMC-5506GA_FMC-5507GA质量流量计OMEGA欧米茄


 The FMC-5000 Coriolis Mass Flow Meter is designed according to the Coriolis Force Principle. It is widely used for flow measurements and custody transfer in many industries such as petroleum, petrochemical, chemical, pharmaceutical, pulp and paper, food and dairy, and more. As an advanced flow and density measurement instrument, it is widely used in the measurement of liquids, gases and slurries, and garners a high reputation among customers around the globe. Coriolis meters are typically used in applications like batch control, blending, filling, dosing, custody transfer, process gas measurements, and more.


The FMC-5000 Series Coriolis Meter is designed according to the principle of Coriolis force. Under the alternating current effect, the electromagnetic coils mounted on the measuring tube will make two parallel measuring tubes vibrating at a certain fixed frequency. Whenever mass (either liquid or gas) flows through the measuring tubes, Coriolis force is generated, causing a “bending” or “deflection” in the top of the tubes. This deflection is sensed as a phase shift between two electronic pick-ups mounted on the tubes. The degree of phase shift is directly proportional to the mass flow within the tubes. The mass flow rate can be calculated by detecting the phase shift of the tubes. The temperature is also measured and used for compensation.




Specifications

Flow Range: See charts below

Connection: ANSI, DIN, JIS, or Sanitary Tri-Clamp flanges

Maximum Pressure: 16 bar (230 psi), [Optional: 25 bar (360 psi), 40 bar (580 psi) and 63 bar (913.7 psi)]

Body Material: 304 Stainless Steel

Measuring Tube Material: 316 L SS

Process Temperature Range:

    Integrate Type: -50 to 125°C (-58 to 257°F)

    Remote Type (-R): -50 to 200°C (-58 to 392°F)

Ambient Temperature: -40 to 55°C (-40 to 131°F)

Working Humidity: (5 to 95%) RH at 25°C (77°F)

Flow Accuracy/Repeatability:

    FMC-5100: 0.1/0.05% (Liquid Only)

    FMC-5200: 0.2/0.1% (Liquid Only)

    FMC-5500: 0.5/0.25%

Density Measuring:

    Range: 0.2 to 3.0 g/cm3

    Error: ± 0.002 g/cm3

    Repeatability: 0.001 g/cm3

Temperature Accuracy: ±1.0°C

Protection: NEMA 4X (IP65)

Approvals: CE, RoHS

Communications: RS485 (RTU Modbus?), HART? (-HART option)

Pulse Output: 0 to 10 kHz, ± 0.075% Full Scale

Current Output: 4 to 20 mA, 0.005% Full Scale

Power Supply: 18 to 36 Vdc, 85 to 265 Vac (-AC option), 15 W

FMC-5505GA_FMC-5506GA_FMC-5507GA质量流量计OMEGA欧米茄