精度:对于满量程小于100 SLM ±1% FS的装置,在15~25°C(59~77°F)和

0.7~4.2 kg/cm2(10~60 psia)下具有线性度。对于≥100 SLM的装置,满量程:±1.5% FS,在15~25°C(59~77°F)和 0.7~4.2 kg/cm2(10~60 psia)下在20~100%的范围内具有线性度;在0~20%的范围内为±3% FS。

重复性:± 0.5%满量程

温度系数:0.15% FS/°C

压力系数:每psi 0.01%FS(0.07 bar)

最大压降:50 psid

响应时间:在25%~100%FS范围内,5秒处于设定流量的±2%范围内

最大气压:70 kg/cm2表压(1000 psig)(适用于最高100 SLM的装置); 35 kg/cm2表压(500 psig);最佳1.76 kg/cm(25 psig)

气体和环境温度:5~50°C(41~122°F)

泄露率:对外界环境的最大泄漏率为1×10-7 cc/sec氦气

接液材质:

    铝制流量计:阳极氧化铝,316 SS,黄铜和FKM O形圈

   不锈钢型号:316 SS 和 FKM O型圈

输出信号:

   线性0~5 Vdc:1000 Ω最小负载

   4~20 mA:50~500 Ω 环路电阻,±20 mV 最大噪声

传感器电源:12~26 Vdc @ 800 mA 标准 量程比:40:1

装运重量:1.8 kg (4 lb)

合规性:EN55011 1类,B类;EN50082-1

海拔灵敏度:水平流径,倾斜到20°,校准也不会发生偏移

气体相对湿度:0~70% RH

FMA5412A_FMA5414A_FMA5416A_FMA5418A_FMA5420A流量控制器OMEGA

Accuracy: For devices with a full range of less than 100 SLM +1% FS, at 15-25 C (59-77 F) and


It has linearity under 0.7-4.2 kg/cm_ (10-60 psia). For devices with (+) 100 SLM, the full range: +1.5% FS has linearity in the range of 20-100% under 15-25 C (59-77 F) and 0.7-4.2 kg/cm(10-60 psia) and (+3% FS) in the range of 0-20%.


Repeatability: & plusmn; 0.5% full range


Temperature Coefficient: 0.15% FS/ C


Pressure coefficient: 0.01% FS (0.07 bar) per PSI


Maximum pressure drop: 50 PSID


Response time: In the range of 25%-100% FS, 5 seconds is in the range of +2% of the set flow rate.


Maximum atmospheric pressure: 70 kg/cm2 gauge pressure (1000 psig) (suitable for the device with the highest 100 SLM); 35 kg/cm2 gauge pressure (500 psig); the optimum 1.76 kg/cm (25 psig)


Gas and ambient temperatures: 5-50 degrees C (41-122 degrees F)


Leakage Rate: Maximum Leakage Rate to the External Environment is 1 x 10-7 cc/sec Helium


Contact material:


Aluminum flowmeters: anodic alumina, 316SS, brass and FKM O rings


Stainless steel models: 316SS and FKM O rings


Output signal:


Linear 0~5 Vdc:1000_Minimum Load


4-20 mA:50-500_loop resistance, +20 mV maximum noise


Sensor power supply: 12-26 Vdc @ 800 mA standard range ratio: 40:1


Shipment weight: 1.8 kg (4 lb)


Compliance: EN55011 1, B; EN50082-1


Altitude sensitivity: Horizontal runoff, tilt to 20 degrees, calibration will not occur migration