来宝网Logo

热门词:生物显微镜 水质分析仪 微波消解 荧光定量PCR 电化学工作站 生物安全柜

AED
现在位置首页>自动化仪器仪表>传感器/变送器>差压变送器>Dwyer差压变送器629C-04-CH-P1-E1-S3-3V_629C-05-CH-P1-E1-S3-3V_629C-06-CH-P1-E1-S3-3V
Dwyer差压变送器629C-04-CH-P1-E1-S3-3V_629C-05-CH-P1-E1-S3-3V_629C-06-CH-P1-E1-S3-3V
Dwyer差压变送器629C-04-CH-P1-E1-S3-3V_629C-05-CH-P1-E1-S3-3V_629C-06-CH-P1-E1-S3-3V
  • Dwyer差压变送器629C-04-CH-P1-E1-S3-3V_629C-05-CH-P1-E1-S3-3V_629C-06-CH-P1-E1-S3-3V

Dwyer差压变送器629C-04-CH-P1-E1-S3-3V_629C-05-CH-P1-E1-S3-3V_629C-06-CH-P1-E1-S3-3V

产品报价:询价

更新时间:2021/5/25 8:21:29

地:美国

牌:德威尔

号:629C-04-CH-P1

厂商性质: 贸易型,

公司名称: 上海茂培电子科技有限公司

产品关键词: 629C-06-   629C-06-CH-P1-E1-S3-3V   629C-04-CH-P1-E1-S3-3V   Dwyer   差压变送器  

185
访问人数
0
累计评论


范先生 : (15221105376) (15221105376)

(联系我时,请说明是在来宝网上看到的,谢谢!)


Dwyer差压变送器629C-04-CH-P1-E1-S3-3V_629C-05-CH-P1-E1-S3-3V_629C-06-CH-P1-E1-S3-3V


Dwyer差压变送器629C-04-CH-P1-E1-S3-3V_629C-05-CH-P1-E1-S3-3V_629C-06-CH-P1-E1-S3-3V

629C-03-R1-P1-E5-S3湿/湿压差变送器,量程25 psid,工作压力50 psi,超压250 psi,带远程传感器和10'屏蔽电缆。


629C-03-R5-P1-E5-S3湿/湿压差变送器,量程25 psid,工作压力50 psi,超压250 psi,带远程传感器和10'铠装电缆。


629C-05-R1-P1-E5-S3湿/湿压差变送器,量程100 psid,工作压力200 psi,超压500 psi,带远程传感器和10'屏蔽电缆。


629C-05-R5-P1-E5-S3湿/湿压差变送器,量程100 psid,工作压力200 psi,超压500 psi,带远程传感器和10'铠装电缆。

Dwyer差压变送器629C-04-CH-P1-E1-S3-3V_629C-05-CH-P1-E1-S3-3V_629C-06-CH-P1-E1-S3-3V

  • Service:

  • Compatible gases and liquids.

  • Wetted Materials:

  • Without valve: 316, 316L SS. Additional wetted parts with valve option: Buna-N, silicone grease, PTFE, brass 360, copper, and reinforced copolymer.

  • Accuracy:

  • ±0.5% FS (includes linearity, hysteresis & repeatability)

  • Stability:

  • ±1% FS/year.

  • Temperature Limits:

  • 0 to 200°F (-18 to 93°C).

  • Compensated Temperature Limits:

  • 0 to 175°F (-18 to 79°C).

  • Pressure Limits:

  • See chart on catalog page.

  • Thermal Effect:

  • Avg 0.04%/°F (0.072%/°C) (includes zero and span).

  • Power Requirements:

  • 2-wire: 10 to 35 VDC; 3-wire: 13 to 35 VDC or isolated 16 to 33 VAC (reverse polarity protected).

  • Output Signal:

  • 2-wire: 4 to 20 mA; 3-wire: Field selectable 0 to 5, 1 to 5, 0 to 10, or 2 to 10 VDC.

  • Zero and Units:

  • Push buttons inside conduit enclosure.

  • Response Time:

  • 400 msec.

  • Loop Resistance:

  • Current output: 0 to 1250 Ω (max), Rmax = 50(Vps-10); Voltage output: Minimum load resistance = 5 kΩ.

  • Current Consumption:

  • 28 mA (max).

  • Electrical Connections:

  • Removable terminal block; 1/2" female NPT conduit.

  • Process Connections:

  • 1/4" female or male NPT.

  • Display:

  • Optional 4-1/2 digit LCD field attachable display.

  • Enclosure Rating:

  • Designed to meet NEMA 4X (IP66).

  • Mounting Orientation:

  • Not position sensitive.

  • Weight: