来宝网Logo

热门词:生物显微镜 水质分析仪 微波消解 荧光定量PCR 电化学工作站 生物安全柜

AED
现在位置首页>通用分析仪器>电化学仪器>离子计>现货B-751 LAQUAtwin紧凑型钙离子计,B-751 LAQUAtwin Compact Calcium Ion Meter 3200456570
现货B-751 LAQUAtwin紧凑型钙离子计,B-751 LAQUAtwin Compact Calcium Ion Meter 3200456570
现货B-751 LAQUAtwin紧凑型钙离子计,B-751 LAQUAtwin Compact Calcium Ion Meter 3200456570
  • 现货B-751 LAQUAtwin紧凑型钙离子计,B-751 LAQUAtwin Compact Calcium Ion Meter 3200456570

现货B-751 LAQUAtwin紧凑型钙离子计,B-751 LAQUAtwin Compact Calcium Ion Meter 3200456570

产品报价:询价

更新时间:2023/4/3 18:11:18

地:其他国家

牌:abqindustrial

号:B-751 LAQUAtwin

厂商性质: 生产型,

公司名称: 世联博研(北京)科技有限公司

产品关键词: 3200456570   Compact Calcium Ion Meter   紧凑型钙离子计   B-751 LAQUAtwin   现货  

555
访问人数
0
累计评论


王荣 : (18618101725) (18618101725)

(联系我时,请说明是在来宝网上看到的,谢谢!)


B-751 LAQUAtwin Compact Calcium Ion Meter 3200456570

B-751 LAQUAtwin紧凑型钙离子计


Horiba B-751 LAQUAtwin Compact Calcium Ion Meter Part # 3200456570


Autocalibration function recognizes standards and is user-selectable for either one or two-point calibration. Measurement range 40ppm - 4000ppm. For submersible and special small sample or solid sample applications.


Temperature compensation



Only compact meter for a quick measurement of calcium ion using ion selective membrane.Flat sensor technology and 60 years of sensor engineering realizes a reliable and direct measurement of a drop of the sample from 0.3mL. Use sampling sheet (sold separately) to measure down to 0.05mL or more.Unique sensor mechanism realizes direct measurement of solid, viscous, powder samples. No need for a beaker to calibrate or measure. Just drop the standards and sample on the flat sensor, saves you time and minimize wasting your precious sample.This lightweight, pocket-sized meter is suitable for research and industrial applications in diverse fields.

Applications include:
Soil and sap testing for improved agriculture; food testing*

* Detection of ions in water only; electrolytes in oils cannot be measured. Ion measurement can be affected by non-target ions.

line
Features 
line

  • Autocalibration function recognizes standards and is user-selectable for either one- or two-point calibrations.

  • Auto range change

  • Temperature compensation

  • IP67 waterproof

  • Auto hold

  • Automatic power off ?30 minutes)

line
Specifications
line

MODEL

B-751



Measurement principle

Ion electrode method



Minimum 
sample volume

0.3mL or more*1



Measurement range

40 to 4000 ppm(mg/L)(10-3 to 10-1 mol/L)



Display range

0 to 9900ppm(mg/L)*2



Range and Resolution
(Valid numbers)

?0 to 1.0ppm : 0.1ppm
?0 to 99ppm : 1ppm
?100 to 990ppm : 10ppm
?1000 to 9900ppm : 100ppm



Calibration

Two-point*3



Accuracy

±20% of reading value.*4



Functions

Auto range change?Temperature compensation?Waterproof*5?Reading locking ?Automatic power off ?30 minutes?

Display

Custom (monochrome) Digital LCD



Operating
temperature/humidity

5 to 40?C, 85% or less in relative humidity  (no condensation)



Power

CR2032 batteries (x2)



Battery life

Approx. 400 hours in continuous use



Main Material

ABS epoxy



Dimensions
/Mass

164mm × 29mm × 20mm  (excluding projections)?/ Approx. 50 g (meter only, without batteries)



Accessories included

2 CR2032 batteries/1 Pipette/Instruction manual/Quick manual/Storage case/Standard solution
(150ppm&2000ppm)(14mL)/5 pieces of Sampling sheetB



*1 Smaller amount(0.05mL or more) can be measured with the sampling sheet B.  (Please close the light shield cover. If a sample that contain particulate, please use ”Sampling sheet holder” (sold separately))
*2 When the measured value is out of the measurement range, the displayed value blinks. It should be used only as a guide.
*3 Selectable between one-point and two-point calibrations. 
*4 Repeatability in measurement of a standard solution after calibration using the same standard solution.
*5 IP67?no failure when immersed in water at a depth of 1 meter for 30 minutes. But the product can not be used underwater.


The ion electrode may be subject to interference from other ionic species. The selectivity coefficient reflects the affinity between each ionic species and the electrode, and is used to correct for the influence of competing ions. Please see the Interfering ion influence ? pH range for further details.

line
Related Products
line

Calcium Ion Sensor S050related

line

Standard solution (Calcium Ion 2000ppm) Y051Hrelated

line

Standard solution (Calcium Ion 150ppm) Y051Lrelated

line

Sampling sheet B Y046related

line

Sampling sheet holder (for LAQUAtwin) Y048related

现货B-751 LAQUAtwin紧凑型钙离子计,B-751 LAQUAtwin Compact Calcium Ion Meter 3200456570现货B-751 LAQUAtwin紧凑型钙离子计,B-751 LAQUAtwin Compact Calcium Ion Meter 3200456570现货B-751 LAQUAtwin紧凑型钙离子计,B-751 LAQUAtwin Compact Calcium Ion Meter 3200456570