现在位置首页>自动化仪器仪表>电工仪器仪表>数据记录仪>OM-DAQXL-1-EW-NA_OM-DAQXL-2-EW-NA_OM-DAQXL-1-NA-CAL-3_OM-DAQXL-2-CN数据记录器OMEGA
OM-DAQXL-1-EW-NA_OM-DAQXL-2-EW-NA_OM-DAQXL-1-NA-CAL-3_OM-DAQXL-2-CN数据记录器OMEGA
OM-DAQXL-1-EW-NA_OM-DAQXL-2-EW-NA_OM-DAQXL-1-NA-CAL-3_OM-DAQXL-2-CN数据记录器OMEGA
  • OM-DAQXL-1-EW-NA_OM-DAQXL-2-EW-NA_OM-DAQXL-1-NA-CAL-3_OM-DAQXL-2-CN数据记录器OMEGA

OM-DAQXL-1-EW-NA_OM-DAQXL-2-EW-NA_OM-DAQXL-1-NA-CAL-3_OM-DAQXL-2-CN数据记录器OMEGA

产品报价:询价

更新时间:2021/5/25 8:21:29

地:美国

牌:欧米茄

号:OM-DAQXL

厂商性质: 贸易型,

公司名称: 上海茂培电子科技有限公司

产品关键词: 触摸屏数据记录仪   OM-DAQXL   欧米茄   数据记录仪   omega  

948
访问人数
0
累计评论


范先生 : (15221105376) (15221105376)

(联系我时,请说明是在来宝网上看到的,谢谢!)


OM-DAQXL-1-EW-NA_OM-DAQXL-2-EW-NA_OM-DAQXL-1-NA-CAL-3_OM-DAQXL-2-CN数据记录器OMEGA

规格




屏幕:7英寸,TFT,带塑料触笔的电阻式触摸屏




橡胶套:黑色




模拟输入类型:热电偶、热敏电阻、电阻式温度检测器、应变计、直流电压、直流电流




热电偶类型:J、K、T、E、R、S、B、C、N




热电偶精度:




J型或K型:±(0.15%的RDG+1.1°C)




T、E或N型:±(0.15%的RDG+1.7°C)




R、S、B或C型:±(0.15%的RDG+2.0°C)




RTD类型:PT100、PT500、PT1000(0.00385或0.00392曲线);2线、3线或4线




RTD精度:±(0.25%的RDG+1°C)




热敏电阻类型:2252Ω/10kΩ




热敏电阻精度:±1.0°C




直流电压输入范围:±50 mV,±100 mV,±1 V,±5 V,±10 V,±20 V,±50 V




直流电流输入范围:±20 mA




直流电压/电流精度:±0.1%fs




应变计类型:100Ω全桥、350Ω全桥




应变计励磁:5V、10V




OM-DAQXL-1-EW-NA U OM-DAQXL-2-EW-NA U OM-DAQXL-1-NA-CAL-3 U OM-DAQXL-2-CN数据记录器Omega




数字输入类型:脉冲/频率




频率/脉冲输入:0至250 kHz




频率精度:±2赫兹


Sampling Rate: 125 s/sec (Max) to 1 s/hour (Min)

Maximum Sampling Rate per Number of Channels (Analog and Digital):

   1 Channel: 125 s/sec

   2 Channels: 50 s/sec

   4 Channels: 25 s/sec

   8 Channels: 10 s/sec

   16 Channels: 5 s/sec

Logging Rate: 125 s/sec (Max) to 1 s/hour (Min)

Maximum Logging Rate per Number of Channels (Analog and Digital):

   1 Channel: 125 s/sec

   2 Channels: 50 s/sec

   4 Channels: 25 s/sec

   8 Channels: 10 s/sec

   16 Channels: 5 s/sec


Excitation to Power External Transmitter: 24 Vdc @ 50 mA output–set in data session setting

Filter Options: Per channel selectable moving average filter: None, 2, 5, 10, 20 or 100 samples

Number of Samples for Moving Average Filter per Channel: Up to 50 samples

Math (Virtual) Channels: 8 or 16

Digital Inputs: 4 Schmitt trigger based inputs

   Range: 0 to 24 Vdc single-ended

   Logic High Threshold: 2.5V

   Logic Low Threshold: 1.5V

Digital Outputs: 4 channels, open collector, 5V @ 50 mA

Alarm Output: 4, Open collector, 30V @ 500 mA

Alarms per Channel: Two

Alarm Types: High, low, windows in, windows out, open sensor

Alarm Latching: Settable in alarm menu

On Alarm Event: Map to 4 alarm outputs, take screen shot, sound buzzer

Logging Conditions: On command or based on trigger conditions

Start and Stop Trigger Conditions: Timer, date and time, weekday and time, alarm output, external trigger

Memory:

   Internal: 1 GB

   SD Card: 32 GB

   USB Drive: 32 GB

USB Ports: One host and one device

Battery: Rechargeable lithium-ion; 7.2V @ 4.8 Ah

Battery Life: 4 to 8 hours based on display setting

DC Adaptor: 12 Vdc @ 5A

Operating Environment: 0 to 50°C (32 to 122°F), 0 to 95%RH non-condensing

General Dimensions: 28.6 L x 15.24 H x 6.35 cm D (9 x 6 x 2.5")

Weight: 1.13 kg (2.5 lbs)

OM-DAQXL-1-EW-NA_OM-DAQXL-2-EW-NA_OM-DAQXL-1-NA-CAL-3_OM-DAQXL-2-CN数据记录器OMEGA