来宝网Logo

热门词:生物显微镜 水质分析仪 微波消解 荧光定量PCR 电化学工作站 生物安全柜

AED
现在位置首页>自动化仪器仪表>温度仪表>温度仪表校验装置>CL542-PLUS通用热电偶校准器Omega欧米茄
CL542-PLUS通用热电偶校准器Omega欧米茄
CL542-PLUS通用热电偶校准器Omega欧米茄
  • CL542-PLUS通用热电偶校准器Omega欧米茄

CL542-PLUS通用热电偶校准器Omega欧米茄

产品报价:询价

更新时间:2021/5/25 8:21:29

地:美国

牌:欧米茄

号:CL542-PLUS

厂商性质: 贸易型,

公司名称: 上海茂培电子科技有限公司

产品关键词: CL542-PLUS   欧米茄   omega   热电偶校准器   校准器  

777
访问人数
0
累计评论


范先生 : (15221105376) (15221105376)

(联系我时,请说明是在来宝网上看到的,谢谢!)


CL542-PLUS通用热电偶校准器Omega欧米茄

With the CL542-PLUS you can check and calibrate all your thermocouple instruments and measure thermocouple sensors.


Calibrate Directly in Temperature (°C and °F)

Stop carrying around a millivolt source and thermocouple tables. The CL542-PLUS works with the thermocouples you use including Types J, T, E, K, R, S, B, N, G, C, D, L (J-DIN), U (T-DIN) and Platinel II. Easily set any value quickly to within 0.1° with the adjustable digital potentiometer “DIAL” plus store any three temperatures for instant recall with the check switch. 


Calibrate Quickly with Automatic Output Stepping

Choose between 2, 3, 5, 11 and 21 steps to automatically increment the output in 100%, 50%, 25%, 10% or 5% of span.


Compatible with All Process Instruments

Connect directly to the thermocouple inputs of smart transmitters, PLCs, DCS and multichannel recorders and verify their outputs or displays. Carry it without worry—it comes protected with a rubber boot and rugged, low profile switch. Easy to operate even in the dark areas of the plant with the backlit display.

CL542-PLUS通用热电偶校准器Omega欧米茄

SPECIFICATIONS

(Unless otherwise indicated all specifications are rated from a nominal 23°C, 70% RH for 1 year from calibration)

Accuracy: ± (0.008% of Reading + 0.006 mV)

Cold Junction Compensation: ± 0.16°F (±0.1°C)

Millivolt Range: -13.000 to 80.000 mV

Operating Temperature Range: -25 to 60°C (-10 to 140°F)

Relative Humidity Range: 10% ≤RH ≤90% (0 to 35°C), non-condensing; 10% ≤RH ≤70% (35 to 60°C), non-condensing

Dimensions: 143 L x 76.2 W x 40.64 mm H (5.63 x 3.00 x 1.60")

Weight: 12.1 ounces (including boot and batteries)

Power: 4 "AA" Alkaline 1.5V (LR6) (included)

Battery Life: 50 Hours, low battery low battery indication with nominal 1 hour of life left. Protection against misconnection over-voltage protection to 60 Vdc (rated for 30 seconds)

Display: High contrast graphic LCD. LED backlighting for use in low lit areas.


Read

Input Impedance: > 10 Megohms

Open Thermocouple Threshold: 10,000 Ω nominal

Pulse: <10 microamp pulse for 300 milliseconds

Normal Mode Rejection: 50/60 Hz, 50 dB

Common Mode Rejection: 50/60 Hz, 120 dB Source

Output Impedance: < 0.3 Ω

Source Current: > 20 mA (drives 80 mV into 10 Ω)

Noise: ≤4 microvolts p-p for frequencies of 10 Hz or below

CL542-PLUS通用热电偶校准器Omega欧米茄