来宝网Logo

热门词:生物显微镜 水质分析仪 微波消解 荧光定量PCR 电化学工作站 生物安全柜

AED
现在位置首页>实验室服务>实验室服务>生物芯片服务>三维聚合物修饰 生物芯片 基片
三维聚合物修饰 生物芯片 基片
三维聚合物修饰 生物芯片 基片
  • 三维聚合物修饰 生物芯片 基片

三维聚合物修饰 生物芯片 基片

产品报价:150元

更新时间:2017/3/8 14:28:22

地:德国

牌:Schott

号:1167904

厂商性质: 生产型,贸易型,服务型,

公司名称: 广州芯奥光电科技有限公司

产品关键词: 、蛋白质芯片载体   三维薄膜涂层   蛋白质芯片   生物芯片  

1406
访问人数
0
累计评论


曾先生 : (18566239007) (020-82510371)

(联系我时,请说明是在来宝网上看到的,谢谢!)


Three-dimensional polymer coating


NEXTERION? Slide P

 
SCHOTT specifically developed NEXTERION? Slide P as a dedicated slide surface for printing low density antibody microarrays. NEXTERION? Slide P produces excellent signal-to-background ratios, and exceptionally wide dynamic ranges compared to conventional “two-dimensional” coatings through a unique combination of low non-specific binding characteristics, and high probe loading capacity. The permeable, polymer coating has a large immobilization capacity, and helps to preserve and protect the antibody structure, thus ensuring high specificity and affinity. The robust coating matrix is fully compatible with commercial microarray printers and scanners. A simple printing and processing protocol is available making NEXTERION? Slide P easy to use.


Overview

Type of coatingImmobilization methodTypical probesOrdering information
NEXTERION?productBarcode optionItem numberSlides per pack
3-D polymer surfaceAmine reactive chemistry 

Covalent binding
AntibodiesSlide PLaser116790425
Key product features
? Optimised substrate for printing low density antibody microarrays
? High probe loading capacity
? Extremely low non-specific binding characteristics
? Superior performance for analysis of serum samples
? High probe loading capacity
? Compatible with all common microarray printers and scanners
Typical applications
? Validation of serum protein profiles
? Target / biomarker identification
? Proteome expression profiling
? Target / biomarker validation
? Protein expression profiling
? Oncoproteomic profiling
? Cytokine quantification
? Profiling disease states
? Sandwich assays
Suitable probe types
? Polyclonal antibodies
? Monoclonal antibodies
? Recombinant antibodies
? Recombinant antibody fragments (scFab, scFv, etc.)
 


Immobilization chemistry

Coating chemistry of NEXTERION polymer coated microarray slides
The coating on the SCHOTT NEXTERION? Slide P is a three-dimensional, hydrophilic polymer activated with N-Hydroxysuccinimide (NHS) esters to provide covalent immobilisation of amine groups. All NEXTERION?microarray slides are manufactured from a high quality, low-fluorescence glass coated with low-fluorescence coatings. However the non-specific binding of assay components, especially from serum samples, still remains an important contributor to the off feature background for many microarray applications. For most types of slide coatings the post-print processing protocol involves a method of adsorptive blocking to reduce non-specific binding; however these procedures are difficult to perform in a consistent manner. 
The NEXTERION? Slide P coating has been engineered to exhibit an extremely low intrinsic non-specific background without the need for blocking. This was achieved by using a special polymer that is extremely resistant to non-specific binding. During in-house tests run by SCHOTT, NEXTERION? Slide P had the lowest background signal of any microarray slide coating ever tested. The polymer coating has a three-dimensional structure; with NHS-ester reactive groups attached to the hydrophilic polymer layer. The surface-exposed amino-groups on the antibodies react immediately and irreversibly with the NHS-ester groups forming covalent bonds. The polymer coating maintains the immobilised antibodies in a quasi-liquid environment that maintains their functionality and specificity. The polymer, combined with the end-point attachment, orients the immobilized bio-molecules away from the glass facilitating the interactions of the attached antibodies with the target antigens in the assay sample.
 


Product details

Highly reproducible coating
NEXTERION? Slide P is fabricated using a proprietary deposition process developed by SCHOTT to produce a uniform and reproducible polymer coating on one side of a high quality borosilicate glass slide. All slides are individually examined for physical defects and the absence of particle contamination before and after coating. The coating is applied in a tightly controlled, Class 100 clean room facility, resulting in coated slides with highly uniform surface properties and low auto-fluorescence. 

Excellent spot morphology and signal-to-background ratios
NEXTERION? Slide P provides excellent spot morphologies and reproducible spot sizes over a wide range of probe concentrations.
Spot morphology of NEXTERION polymer coated microarray slides
Figure shows scanned images of NEXTERION? Slide P evaluated in an anti-IgG/IgG interaction study over a range of probe concentrations dissolved in NEXTERION? Spot PB and a phosphate print buffer.

The NEXTERION? Slide P coating is relatively hydrophilic, and care must be taken to ensure that the spot-to-spot pitch distance is set high enough to avoid spot merging.
Printing bufferSpot diameter 
(split pins, SMP3)
NEXTERION? Spot PB160 μm
50% DMSO, borate pH 8.090 μm
Packaging and storage
NEXTERION? Slide P are packaged in chemically stable plastic boxes and sealed under an inert atmosphere. The slides are ready-to-use from the box, and are stable for up to 12 months in the sealed packaging when stored at –20oC. .


Format
NEXTERION? Slide P is available in packs of 25-slides with Code 128 barcodes enabling automated sample tracking. The identical P coating is also available in either 16-well, 48-well or 96-well formats. For further information refer to the section “Multi-well formats”.

Compatible reagents

Protocol stepRecommended NEXTERION?productsAlternativesRecommended concentrations
Spotting (Protein)-150 mM phosphate, pH 8.5, 5 % glycerol, 0.1 mg/ml BSA, 0.01% sarcosyl or Tween 20?

NEXTERION? Spot PB
(composition can be provided)

Protein concentration 0.1 to 1 mg/mL
Spotting (DNA)NEXTERION? Spot
(1066029)
100 mM borate (pH 8.0),
50 % DMSO
Oligonucleotides: 20 μM
Spotting (Peptides)-10 – 50 % DMSO 
Chemical deactivation
of unreacted
NHS-esters
-50 mM ethanolamine in 50 mM
sodium borate buffer pH 8.0 – 9.0
 
Incubation (Protein)-137 mM NaCl, 2.7 mM KCl,
4.3 mM Na2HPO4, 1.4 mM KH2PO4,
pH 7.5 with 0.5 % Tween20?
 
Hybridization (DNA)NEXTERION? Hyb
(1066075)
2x SSC containing 0.1 % SDS
and 0.1 % salmon sperm DNA

NEXTERION? Oligo Hyb
(composition can be provided)

 


广州芯奥光电科技有限公司

| 第9

手机:18566239007

联系人:曾先生

电话:020-82510371

传真:020-82510370

QQ:76550682

(联系我时,请说明是在来宝网上看到的,谢谢!)