来宝网Logo

热门词:生物显微镜 水质分析仪 微波消解 荧光定量PCR 电化学工作站 生物安全柜

AED
现在位置首页>实验室原料试剂耗材>生化试剂>ELISA试剂盒>96T小鼠可溶性核因子κB受体活化因子配基(sRANKL)ELIS
96T小鼠可溶性核因子κB受体活化因子配基(sRANKL)ELIS
96T小鼠可溶性核因子κB受体活化因子配基(sRANKL)ELIS
  • 96T小鼠可溶性核因子κB受体活化因子配基(sRANKL)ELIS

96T小鼠可溶性核因子κB受体活化因子配基(sRANKL)ELIS

产品报价:询价

更新时间:2017/2/10 9:20:19

地:美国

牌:

号:96T

厂商性质: 生产型,贸易型,服务型,

公司名称: 厦门慧嘉生物科技有限公司

产品关键词:

675
访问人数
0
累计评论


陈先生 : (18906011628) (0592-6020891)

(联系我时,请说明是在来宝网上看到的,谢谢!)


 

厦门慧嘉生物长期专业销售ELISA试剂盒\Santa \ Abcam \ Cst \ jackson \ Pierce \ Sigma \ Amresco \Qiagen \ Cayman \ abnova \ millipore \ invitrogen \ merk \ ebioscience \prospec \ peprotech细胞因子特价专供。等生物试剂产品。实验为大,诚信经营,为客户提供“最高质量的产品”和“最优质的服务:18906011628 0592-6020891 QQ: 1193952234 1048735792 或登陆http://www.biohj.com(向客服人员索取原版说明书)。欢迎广大老师来询!

检测范围:

Request Information

灵敏度:

Request Information

反应时间:

1-3h

所需样本体积:

50-100ul

检测波长:

450 nm

说明书:

(向客服人员索取原版说明书)

原理 :

This assay employs the quantitative sandwich enzyme immunoassay technique. Antibody specific for ACHE has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and any ACHE present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for ACHE is added to the wells. After washing, avidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of ACHE bound in the initial step. The color development is stopped and the intensity of the color is measured.

特异性:

This assay has high sensitivity and excellent specificity for detection of Rat ACHE. No significant cross-reactivity or interference between Rat ACHE and analogues was observed.

精密度:

Intra-assay Precision (Precision within an assay): CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess.
Inter-assay Precision (Precision between assays): CV%<10%
Three samples of known concentration were tested in twenty assays to assess.

样本搜集及储存:

Serum: Use a serum separator tube (SST) and allow samples to clot for two hours at room temperature or overnight at 4°C before centrifugation for 15 minutes at 1000 ×g. Remove serum and assay immediately or aliquot and store samples at -20°C or -80°C. Avoid repeated freeze-thaw cycles.
Plasma: Collect plasma using EDTA, or heparin as an anticoagulant. Centrifuge for 15 minutes at 1000 ×g at 2-8°C within 30 minutes of collection. Assay immediately or aliquot and store samples at -20°C or -80°C. Avoid repeated freeze-thaw cycles.

检测步骤:

Bring all reagents and samples to room temperature before use. Centrifuge the sample again after thawing before the assay. It is recommended that all samples and standards be assayed in duplicate.
1. Prepare all reagents, working standards, and samples as directed in the previous sections.
2. Refer to the Assay Layout Sheet to determine the number of wells to be used and put any remaining wells and the desiccant back into the pouch and seal the ziploc, store unused wells at 4°C.
3. Add 100μl of standard and sample per well. Cover with the adhesive strip provided. Incubate for 2 hours at 37°C. A plate layout is provided to record standards and samples assayed.
4. Remove the liquid of each well, don't wash.
5. Add 100μl of Biotin-antibody (1x) to each well. Cover with a new adhesive strip. Incubate for 1 hour at 37°C. (Biotin-antibody (1x) may appear cloudy. Warm up to room temperature and mix gently until solution appears uniform.)
6. Aspirate each well and wash, repeating the process two times for a total of three washes. Wash by filling each well with Wash Buffer (200μl) using a squirt bottle, multi-channel pipette, manifold dispenser, or autowasher, and let it stand for 2 minutes, complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining wash Buffer by aspirating ordecanting. Invert the plate and blot it against clean paper towels.
7. Add 100μl of HRP-avidin (1x) to each well. Cover the microtiter plate with a new adhesive strip. Incubate for 1 hour at 37°C.
8. Repeat the aspiration/wash process for five times as in step 6.
9. Add 90μl of TMB Substrate to each well. Incubate for 15-30 minutes at 37°C. Protect from light.
10. Add 50μl of Stop Solution to each well, gently tap the plate to ensure thorough mixing.
11. Determine the optical density of each well within 5 minutes, using a microplate reader set to 450 nm. If wavelength correction is available, set to 540 nm or 570 nm. Subtract readings at 540 nm or 570 nm from the readings at 450 nm. This subtraction will correct for optical imperfections in the plate. Readings made directly at 450 nm without correction may be higher and less accurate.

结果计算:

Using the professional soft "Curve Exert 1.3" to make a standard curve is recommended, which can be downloaded from our web.
Average the duplicate readings for each standard and sample and subtract the average zero standard optical density.
Create a standard curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a standard curve by plotting the mean absorbance for each standard on the x-axis against the concentration on the y-axis and draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the ACHE concentrations versus the log of the O.D. and the best fit line can be determined by regression analysis. This procedure will produce an adequate but less precise fit of the data.
If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor.

小鼠可溶性核因子κB受体活化因子配基(sRANKL)ELISA试剂盒
小鼠降钙素(CT)ELISA试剂盒
小鼠脱氢表雄酮硫酸酯(DHEA-S)ELISA试剂盒
小鼠内皮素1(ET-1)ELISA试剂盒
小鼠雌二醇(E2)ELISA试剂盒
小鼠皮质醇(Cortisol)ELISA试剂盒
小鼠促甲状腺素(TSH)ELISA试剂盒
小鼠儿茶酚胺(CA)ELISA试剂盒
小鼠白细胞介素-27(IL-27)ELISA试剂盒
小鼠白细胞介素-23(IL-23)ELISA试剂盒
小鼠脂蛋白α(Lp-α)ELISA试剂盒
小鼠大内皮素(Big ET)ELISA试剂盒