来宝网Logo

热门词:生物显微镜 水质分析仪 微波消解 荧光定量PCR 电化学工作站 生物安全柜

现在位置首页>医疗器械>眼科>眼压计> 俄罗斯diaton眼睑式眼压仪

商品编号:54827
分享

俄罗斯diaton眼睑式眼压仪

价    格:询价

产    地:更新时间:2019/7/15 13:41:34

品    牌:Diaton Tonometer型    号:

状    态:正常点击量:1976

15665882320
联系我时,请说明是在来宝网上看到的,谢谢!

济南济威生物技术有限公司

联 系 人:张经理

电     话:0531-81307925

传     真:

等     级: (第 1年)

性     质:生产型,

联系我时请说在来宝网上看到的,谢谢!




diaton tonometer provides high reliability of measuring results and makes it possible to diagnose glaucoma on the early stage and appoint necessary treatment and medicines.
diaton 眼压仪提供高可靠性的测量结果,使早期阶段能够诊断青光眼并给予必要的治疗和药物。

The unique methodology of intraocular pressure measuring through the eyelid applied in the device provides new resources in ophthalmotonometry, simplicity and safety of tests.
本仪器应用通过眼睑测量眼内压的独特方法为眼压测量提供了新资源,简单,检测安全。

Transpalpebral "diaton" tonometer is effective and irreplaceable in various situations:
“diatom” 眼睑式眼压仪在许多情况下是有效的和不可替代的:
 

  • screening examinations of the patients病人筛选检查
  • IOP control during selection of adequate medicines选择足量药物中控制IOP
  • IOP measuring in the presence in a patient of chronical conjunctivitis, erosions, edema and cornea dimness在慢性结膜炎、糜烂、水肿和角膜混浊时测量IOP
  • IOP measuring in patients after corneal surgeries角膜手术后测量IOP
  • ophthalmotone day monitoring每日眼压监测
  • IOP measuring in immobilized patients and in children不能移动的病人和儿童IOP测量
  • IOP measuring during contact correction (lenses are not taken out).接触镜矫正(镜片未取出)中测量IOP

 

New diaton tonometer has a number of indisputable advantages, making the IOP measuring process handy for the doctor and comfortable for the patient.
新型的diaton 眼压仪具有许多无可争辩的优点,使得IOP测量过程医生方便和病人舒服。

Features 特点 diaton Goldmann Tonometer Shiotz Tonometer Air-jet Tonopen
No contact with the cornea不接触角膜 +        
Portability携带方便 +   +   +
Displays independence from cornea's crookedness.显示与角膜曲度无关 +        
Digital IOP indication 数字IOP显示 +     + +
Measurement in sitting position 坐位测量 + +   + +
Measurement in reclining position 躺位测量 +   +   +
Short-time measurement 测量时间短 +     +  
Sterilization is not required 无需消毒 +     +  
Anesthesia is not required 无需麻醉 +     +  

 

Comparison tests of diaton tonometer and Goldman tonometer are the evidence of high reliability of diaton tonometer displays.
Diaton眼压仪与Goldman眼压仪比较测验为证明diaton眼压仪的高可靠性的证据。

SPECIFICATIONS 规格

Measurement range测量范围 5-60 mmHg
Measurement error 测量误差 Limit of the admissible measurement error in the range, not more
容许测量误差范围不超过:
5 ~ 20 mmHg - ±2 mmHg;
20~ 60 mmHg - ±10%
 
The time of a single measurement, s, not more
单次测量时间不超过
3秒
Supply voltage 电源 3V
Number of measurements using one battery set, not less
使用一个电池测量次数不少于
1500
Service life, not less 使用年限不少于 8年
Weight 重量 89g
Dimensions, not more 大小不超过 174 x 26 x 20 mm

 

Method for measuring the intraocular pressure through the eyelid and device for realizing the same are protected with the Patent of Russia #2123798, United States Patent # US 6,394,954 B1 and Patent of Japan #3593314.
通过眼睑测量眼内压的方法和实现检测的设备受俄罗斯专利#2123798, 美国专利 #US 6,394,954 B1 和日本专利#3593314保护。





猜你喜欢