WHT-330 WHT-333 WHT-31A WHT-32A 美国Dwyer德威尔 温湿度变送器

The compact SERIES WHT Humidity/Temperature Transmitter is designed to

withstand the elements. A removable sintered filter protects the polymer capacitance

sensor from solid objects that may come in contact with the transmitter. The transmitter

is available with 4 to 20 mA or 0 to 10 VDC output signals for both temperature and

humidity. This transmitter is ideal for measuring outside air temperature and humidity

levels for air handling economizer applications.



产品参数

WHT-330 WHT-333 WHT-31A WHT-32A 美国Dwyer德威尔 温湿度变送器

Relative Humidity Range: 0 to 100% RH.

Temperature Range: -40 to 140°F (-40 to 60°C).

Accuracy, RH: ±3% 20 to 80% RH, ±4% @ 10 to 20%, 80 to 90%.

Accuracy, Temp Models with 4 to 20 mA Temp. Output: ±0.9°F @ 72°F (±0.3°C @ 25°C).

Accuracy, Temp Models with Passive Thermistor Temp Sensor: ±0.4°F @ 77°F (±0.22°C @ 25°C).

Hysteresis, RH: ±1%.

Repeatability, RH: ±0.1% typical.

Temperature Limits: -40 to 140°F (-40 to 60°C).

Storage Temperature: -40 to 176°F (-40 to 80°C).

Compensated Temperature Range, RH: -4 to 140°F (-20 to 60°C).

4-20 mA Loop Powered Models: Power Requirements: 10 to 35 VDC; Output Signal: 4 to 20 mA.

0 to 10 V Output Models: Power Requirements: 15 to 35 VDC or 15 to 29 VAC; Output Signal: 0 to 10 V @ 5 mA max.

0 to 5 V Output Models: Power Requirements: 10 to 35 VDC or 10 to 29 VAC; Output Signal: 0 to 5 V @ 5 mA max.

Response Time: 15 seconds.

Electrical Connections: Removable screw terminal block.

Drift: <1% RH/year.

RH Sensor: Capacitance polymer.

Temperature Sensor: 4 to 20 mA output, solid state band gap. Passive output: 10K @ 25°C thermistor (Dwyer curve A).

Enclosure: ABS.

Enclosure Rating: Designed to meet NEMA 3S (IP54).

Weight: 0.3 oz (8.5 g).

Agency Approvals: CE.



产品介绍

WHT-330 WHT-333 WHT-31A WHT-32A 美国Dwyer德威尔 温湿度变送器2.jpg

WHT-330 WHT-333 WHT-31A WHT-32A 美国Dwyer德威尔 温湿度变送器

Relative Humidity Range: 0 to 100% RH.

Temperature Range: -40 to 140°F (-40 to 60°C).

Accuracy, RH: ±3% 20 to 80% RH, ±4% @ 10 to 20%, 80 to 90%.

Accuracy, Temp Models with 4 to 20 mA Temp. Output: ±0.9°F @ 72°F (±0.3°C @ 25°C).

Accuracy, Temp Models with Passive Thermistor Temp Sensor: ±0.4°F @ 77°F (±0.22°C @ 25°C).

Hysteresis, RH: ±1%.

Repeatability, RH: ±0.1% typical.

Temperature Limits: -40 to 140°F (-40 to 60°C).

Storage Temperature: -40 to 176°F (-40 to 80°C).

Compensated Temperature Range, RH: -4 to 140°F (-20 to 60°C).

4-20 mA Loop Powered Models: Power Requirements: 10 to 35 VDC; Output Signal: 4 to 20 mA.

0 to 10 V Output Models: Power Requirements: 15 to 35 VDC or 15 to 29 VAC; Output Signal: 0 to 10 V @ 5 mA max.

0 to 5 V Output Models: Power Requirements: 10 to 35 VDC or 10 to 29 VAC; Output Signal: 0 to 5 V @ 5 mA max.

Response Time: 15 seconds.

Electrical Connections: Removable screw terminal block.

Drift: <1% RH/year.

RH Sensor: Capacitance polymer.

Temperature Sensor: 4 to 20 mA output, solid state band gap. Passive output: 10K @ 25°C thermistor (Dwyer curve A).

Enclosure: ABS.

Enclosure Rating: Designed to meet NEMA 3S (IP54).

Weight: 0.3 oz (8.5 g).

Agency Approvals: CE.