来宝网Logo

热门词:生物显微镜 水质分析仪 微波消解 荧光定量PCR 电化学工作站 生物安全柜

现在位置首页>实验试剂制品>生化试剂>常规生化试剂> RNase-ExitusPlus?(RNA酶污染清除剂)

商品编号:52637
分享

RNase-ExitusPlus?(RNA酶污染清除剂)

价    格:询价

产    地:德国更新时间:2019/7/15 13:41:34

品    牌:AppliChem型    号:A7153

状    态:正常点击量:1571

18210960361
联系我时,请说明是在来宝网上看到的,谢谢!

北京西美杰科技有限公司

联 系 人:方丽初

电     话:010-88597838

传     真:010-88595011

等     级: (第 12年)

性     质:生产型,贸易型,服务型,

联系我时请说在来宝网上看到的,谢谢!




RNase-ExitusPlus™

A7153

Order No. Quantity
A7153,0100 100 ml
A7153,0250 250 ml
A7153,0500 500 ml
A7153,1000 1 L
A7153,1000RF 1 L
A7153,10006 6 x 1 L
A7153,10006RF 6 x 1 L
A7153,2500RF 2,5 L


产品参数

Synonym Decontamination removal solution for RNase, RNase decontamination solution 
HS-No. 38220000 
Storage RT 
LGK 10 - 13 
  replaces RNase-OFF™ and RNase-Exitus 
  • removes RNase contaminations from surfaces 
  • for cleaning of laboratory surfaces 
  • for cleaning of electrophoresis equipment, pipetts, reaction tubes etc. 
  • supplied in spray bottles or refill bottles (RF) 
  special, new features 
  • non-enzymatic degradation of RNase by catalytic and cooperative effects of the components 
  • All components of RNase-ExitusPlus™ are readily bio-degradable and not harmful or toxic for humans. 
  • Doesn''t contain aggressive mineralic acids or alkaline substances 
  • No toxic fumes. Contains low concentration of alcohol. 
  * Attention: New Formulation! 


产品介绍

RNase-ExitusPlus™ is a non-alkaline, non-corrosive and non-carcinogenic cleaning solution that is highly active against RNase contamination. RNase-ExitusPlus™ has been demonstrated to inactivate more than 20 μg of RNase A dried onto the bottom of a microcentrifuge tube. RNase-ExitusPlus™ is stable for approx. 15 months.
RNase-ExitusPlus™ is ready-to-use for eliminating RNase from any surface including the interior of microcentrifuge tubes. By following the simple decontamination instructions below, RNase is completely inactivated and removed. RNase-ExitusPlus™ should be stored at room temperature; at lower temperatures a precipitate may form which is easily brought into solution at 37°C.
Instructions: To decontaminate pipettors: Following manufacturers instructions; remove the shaft from the pipettor and remove seals and gaskets from the shaft. Soak the shaft for one minute in RNase-ExitusPlus™, rinse the shaft thoroughly with water, let dry and reassemble.
To decontaminate laboratory surfaces: Apply RNase-ExitusPlus™ directly to the lab surface. Wipe thoroughly with a paper towel, rinse with water and dry with a clean paper towel.
To decontaminate laboratory apparatus: Generously apply RNase-ExitusPlus™ to a paper towel and wipe all exposed surfaces of the apparatus thoroughly. Rinse with water and dry with a clean paper towel. To clean small parts, briefly soak them in RNase-ExitusPlus™, rinse with water and dry.
To decontaminate plastic and glass vessels: Add ample RNase-ExitusPlus™ to enable coating the entire surface of the vessel by swirling or vortexing. Discard the solution and rinse vessels thoroughly two times with distilled water.
RNase-ExitusPlus™ is a registered trademark of AppliChem GmbH.



猜你喜欢