来宝网Logo

热门词:生物显微镜 水质分析仪 微波消解 荧光定量PCR 电化学工作站 生物安全柜

现在位置首页>行业专用>行业专用仪器/仪表>仪器> CCT-22-0/400C_CCT-23-0/1000C_CCT-24-0/200C_CCT-24

商品编号:75028
分享

CCT-22-0/400C_CCT-23-0/1000C_CCT-24-0/200C_CCT-24

价    格:询价

产    地:美国更新时间:2021/9/10 14:45:14

品    牌:欧米茄型    号:CCT-22-0/400C

状    态:正常点击量:386

15221105376
联系我时,请说明是在来宝网上看到的,谢谢!

上海茂培电子科技有限公司

联 系 人:范先生

电     话:15221105376

传     真:

等     级: (第 9年)

性     质:贸易型,

联系我时请说在来宝网上看到的,谢谢!





CCT-22-0/400C_CCT-23-0/1000C_CCT-24-0/200C_CCT-24-0/300C信号调节器OMEGA

CCT系列DIN轨道信号调节器设计用于接收广泛的输入信号,如交流和直流电压和电流、频率、温度(热电偶和RTD)和过程传感器,并提供0/4至20 mA或0至10 Vdc的标准过程输出。CCT系列采用现代外壳设计,易于安装在标准DIN导轨上。连接安全可靠,输入和输出连接在模块的另一侧。




内部设计


CCT系列采用内部插件三模块系统设计,可灵活选择和更改电源、输入信号和输出信号。该装置提供110伏交流电标准电源,220伏交流电和24伏直流电请咨询销售。



产品参数

CCT-22-0/400C_CCT-23-0/1000C_CCT-24-0/200C_CCT-24-0/300C信号调节器OMEGA

电源:110 Vac(标准);220 Vac或24 Vdc(可选)(所有电源的公差为±10%)


输出:4至20 mA和0至10 Vdc标准;通过跳线选择0至20 mA


精度:≤0.2%或≤0.3,%,取决于型号


响应时间:≤250 ms


隔离:2 kVeff


纹波:≤0.5%


带通:1.5赫兹(-3分贝)


工作环境:-10至60°C(14至140°F)


储存环境:-30至80°C(-22至176°F)


温度系数:≤0.015%/°C


功耗:最大1.5 VA


外壳:聚碳酸酯,RAL 7032;UL 94 V-1,IP40保护


端子外壳:聚碳酸酯,UL 94-2,IP20保护


最大线径:4 mm2(14 AWG)


尺寸:75 H x 45 W x 110 mm D(2.95“x 1.77”x 4.33“)


重量:270克(0.6磅)


安装:DIN轨道46277和EN 50022(35 x 7.5 mm)


产品介绍

CCT-22-0/400C_CCT-23-0/1000C_CCT-24-0/200C_CCT-24-0/300C信号调节器OMEGA

Voltage, Current, Frequency, Resistance, Potentiometer, Thermocouple, RTD and Strain Gage Input Modules

Integrator Modules Convert Voltage or Current to Frequency

Loop Powered Galvanic Isolator Provides 2 kVeff Isolation Between Input and Output

Compatible with Standard 35 mm DIN Rail


The CCT series DIN rail signal conditioners are designed to accept a broad range of input signals, such as ac and dc voltage and current, frequency, temperature (thermocouple and RTD), and process transducers, and provide standard process outputs of either 0/4 to 20 mA, or 0 to 10 Vdc. The CCT series features a modern housing design, that is easily mounted on standard DIN rails. Connections are safely and securely made, with input and output connections on the opposite sides of the module.


Internal Design

The CCT series is designed using an internal plug-in three module system that provides flexibility in selecting and changing the power supply, input signal and output signal. The units are supplied with 110 Vac power standard, Consult sales for 220 Vac, and 24 Vdc power.


Isolation

The three internal modules in each signal conditioner (signal input, signal output and power supply) are isolated up to 2 kVeff.


Outputs

Each CCT series signal conditioner is available with current and voltage output (only one may be used at a time). Available output types include 4 to 20 mA or 0 to 20 mA (jumper-selectable) and 0 to 10 Vdc.


Standard outputs are linear and proportional to the signal input. Thermocouple input modules feature special circuitry to linearize the output to the actual temperature, and not to the non-linear signal produced by thermocouple sensors.


Specifications

Power: 110 Vac (standard); 220 Vac or 24 Vdc (optional) (±10% tolerance on all power supplies)

Output: 4 to 20 mA and 0 to 10 Vdc standard; 0 to 20 mA via jumper select

Accuracy: ≤0.2% or ≤0.3,%, depending on the model

Response Time: ≤250 ms

Isolation: 2 kVeff

Ripple: ≤0.5%

Bandpass: 1.5 Hz (-3 dB)

Operating Ambient: -10 to 60°C (14 to 140°F)

Storage Ambient: -30 to 80°C (-22 to 176°F)

Temperature Coefficient: ≤0.015%/°C

Power Consumption: 1.5 VA max

Enclosure: Polycarbonate, RAL 7032; UL 94 V-1, IP40 protection

Terminal Housing: Polycarbonate, UL 94-2, IP20 protection

Max Wire Size: 4 mm2 (14 AWG)

Dimensions: 75 H x 45 W x 110 mm D (2.95" x 1.77" x 4.33")

Weight: 270 g (0.6 lb)

Mounting: DIN rail 46277 and EN 50022 (35 x 7.5 mm)