美国C.B.S.SCIENTIFIC脂蛋白凝胶电泳Pore Gradie nt Gel Electr


Resolve Lipoprotein Sub-Classes

APPLICATIONS

? Resolution of Lipoprotein subclasses (HDL and LDL)

? Standard PAGE


DESCRIPTION

The Pore Gradient Lipoprotein Electrophoresis System (LPE) is designed to

resolve lipoprotein sub-classes of low density lipoproteins (LDL) and high

density lipoproteins (HDL) based on particle size using non-denaturing pore

gradient gel electrophoresis (1, 2, 3). Other applications include standard

PAGE and short DNA sequencing runs. Temperature control (8°C - 10°C) is

accomplished using a cooling coil in the buffer chamber that is connected

to an external refrigerated water bath. A built-in pump recirculates the buffer

and helps keep the temperature constant.

CBS Scientific has specifically designed this system to be used with pre-cast

non-denaturing acrylamide gradients from Alamo Gels, Inc. Up to four gels

can be run simultaneously. Slots in a specially molded silicone gasket hold

these pre-cast gels in place in the upper reservoir. 3 gel slot plugs are included

in the event the researcher would like to run less than 4 gels at a time.

Precast Non-denaturing Pore-Gradient Polyacrylamide Gels

C.B.S. Scientific offers 2/16, 4/30 and 2/31 percent pre-cast non-denaturing

polyacrylamide gels for high resolution gradient gel electrophoresis. The 2/16

gels are for resolving low-density lipoproteins (LDL’s) over an approximate

molecular weight range of 100,000-5,000,000. The 4/30 gels are for

resolving high-density lipoproteins (HDL’s) over an approximate range of

50,000-2,000,000. The 2/31 combo gels resolve lipoproteins from 50,000-

5,000,000. The pre-cast cassettes are 4.9mm thick with a height and width

of 82mm. Gels are sold in packs of 16, have a 6 month shelf life and should

be kept at 4°C - 8°C.

Glass Plates and Spacers

Glass plates and spacers can be ordered for researchers that desire to pour

their own gradient gels. Glass plates dimensions are 8.2cm wide by 8.2cm

high (cat. #LPG-082). Spacers are 82mm high and have a thicknesses of

2.8mm (cat. #LPS-028).

Sample Applicators

Sample applicators can be ordered with a choice of 12 (cat. #LPE-SL12),

13 (cat. #LPE-SL13), or 18 (cat. #LPE-SL18) wells. Sample applicators are

inserted into the top of the pre-cast gels for sample loading and remain in

place during the electrophoresis.



产品参数

美国C.B.S.SCIENTIFIC脂蛋白凝胶电泳Pore Gradie nt Gel Electr


SPECIFICATIONS

Overall Dimensions

W x D x H (cm)

39 x 12 x 28

Glass Plate Dimensions

W x L (cm)

8.2 x 8.2

Recommended Buffer Volume 3.5 Liters


CAT. # DESCRIPTION

PORE GRADIENT LPE SYSTEM

LPE-4003 Pore Gradient LPE System, CE, Complete System

LPE-4003-220V Pore Gradient LPE System, CE, 220V, Complete System

Related Products

LPE-430-16 4/30% Pore Gradient Polyacrylamide Gels, non-denaturing,

package of 16

LPE-216-16 2/16% Pore Gradient Polyacrylamide Gels, non-denaturing,

package of 16

LPE-231-16 2/31% Pore Gradient Polyacrylamide Gels, non-denaturing,

package of 16

LPE-SL12 Sample Applicator, 12 well

LPE-SL13 Sample Applicator, 13 well

LPE-SL18 Sample Applicator, 18 well

LPG-082 Glass Plates, 82mm(h) x 82mm(w)

LPS-028 Spacer Set, 2.8mm thick x 82mm(h)

EPS-300 X Power Supply, CE, 10-300V, 4-500mA



产品介绍

美国C.B.S.SCIENTIFIC脂蛋白凝胶电泳Pore Gradie nt Gel Electr


Pore Gradient LPE System

LPE-4003

Complete System:

? Base unit/lower buffer reservoir with cooling coil and external

connections for refrigerated water bath

? 4 sample applicators with choice of 12, 13, or 18 wells

? Upper reservoir with 4-slot molded silicone gasket

? Platinum Electrodes

? 3 gel slot plugs for molded silicone gasket. (Plugs are necessary when

running less than 4 gels at a time)

? Safety cover with electrical interlock

? Buffer recycling pump